Worldwide
Search:

What's new in GENESYS 8.11

-

Genesys 8.11 also includes all features found in GENESYS 8.01 and earlier versions. See our Comparison Table of Recent Versions for an easy reference.

New SPECTRASYS system simulator is now available

  • RF System / Architecture design tool
  • Identify the origin, path, and phase of spectral components
  • Over 30 channelized system measurements
  • New graphs: Level diagrams and composite spectrums

GRAPH Improvements

  • Popup (fly-over) tool-tip info; just hover the cursor over a marker or trace.
  • Rectangular Zoom (on rectangular charts)
  • New Marker types:
    • Peak (follows peaks during tuning)
    • Valley (follows valleys during tuning)
    • Bandwidth (automatically measures bandwidth)
    • Relative left and right
    • Standard
  • Added new Marker Properties dialog box (can now enter a marker frequency by X-value)
  • Marker text will no longer overlap other marker text
  • Greatly expanded Graph toolbar
  • Added Mark All Traces toggle (can now mark individual traces)
  • Added level-of-detail simplification to Smith charts (increases rendering speed)
  • Improved graph traces: auto-bold traces, each sweep trace is drawn in a unique color
  • Improved autoscale ranges
  • Improved graph printing

MODELS

  • New COAX cable models
    • CABLE, RG6, RG8, RG9, RG58, RG59, RG214
  • New SYSTEM models
    • RFAMP, MIXERP (passive), MIXERA (active), SPDT, SPST,
    • ATTN (attenuator), ATTN_VAR (variable attenuator),
    • SPLIT2 (2 way splitter / combiner), SPLIT290 (2 way 90° splitter),
    • SPLIT2180 (2 way 180° splitter), SPLIT3, SPLIT4, SPLIT5,
    • LPF_BUTTER (Lowpass Butterworth Filter), LPF_BESSEL (Lowpass Bessel),
    • LPF_CHEBY, LPF_ELLIPTIC, LPF_POLES (Lowpass Pole Zero Filter),
    • BPF_BUTTER (Bandpass Butterworth Filter), BPF_BESSEL (Bandpass Bessel),
    • BPF_CHEBY, BPF_ELLIPTIC, BPF_POLES (Bandpass Pole Zero Filter),
    • HPF_BUTTER (Highpass Butterworth Filter), HPF_BESSEL (Highpass Bessel),
    • HPF_CHEBY, HPF_ELLIPTIC, HPF_POLES (Highpass Pole Zero Filter),
    • BSF_BUTTER (Bandstop Butterworth Filter), BSF_BESSEL (Bandstop Bessel),
    • BSF_CHEBY, BSF_ELLIPTIC, BSF_POLES (Bandstop Pole Zero Filter),
    • DUPLEXER_C (Chebyshev Duplexer), DUPLEXER_E (Elliptic Duplexer)
    • DELAY (Time delay), PHASE (Ideal Phase Shift), CIRCULATOR,
    • ISO (Isolator), COUPLER1 (Single Directional Coupler), COUPLER2 (Dual Directional Coupler), HYBRID1 (90 Degree Hybrid Coupler)
    • LOG_DET (Log Detector), VARAMP (Variable Gain Amplifier),
    • ANTC (Coupled Antenna), PATH (Antenna Path)
  • Improved range warnings

FILTER, A/FILTER, M/FILTER

  • Integrated into GENESYS framework
  • Allows viewing of response while designing filter
  • Allows modification of filter even after integration with larger circuit.  For example, you can tune the order or bandwidth of a filter and watch a SPECTRASYS simulation, which uses that filter update as you tune.
  • Can now synthesize a filter by right-clicking on a part in SCHEMAX

LAYOUT

  • Added GDSII import
  • Added GDSII export
  • Added Step and Repeat function
  • Added ability to edit schematic part parameters from within LAYOUT (on right button menu)
  • Improved Gerber and DXF import

SCHEMAX

  • Added Fit To Page and Center Schematic menu commands
  • Added Synthesis tab to SCHEMAX Part Properties dialog box
    • New - disable parts open / shorted
    • Use any symbol as a sub-network
    • Easily attach an S-Parameter file to any part
  • Expanded System toolbar (many new parts)
  • Local error messages (Orange parts, with right click info)

EMPOWER

  • Improved memory usage

HARBEC

  • Added Temperature
  • More efficient multi-tone

OPTIMIZATION AND YIELD

  • Can now disable Opt targets

TABLES

  • Added the ability for Tables to automatically save data to an external file

Ease-of-use Improvements

  • Improved Zooming

    • Mouse wheel, middle mouse button click and middle double click

    • (Implemented for SCHMAX, LAYOUT, and Graphs)

  • Implemented Workspace tree Copy and Paste (on right button menu)

  • Implemented Workspace tree Drag and Drop to copy and paste workspace items

  • Added Help buttons to dialog boxes

  • Improved Setup Variables dialog box (less confusing)

  • Improved DisCo symbols (for printed output)

  • Improved toolbar icons

Fixes in GENESYS 8.1

Category

Title

Details

Documentation

Added definition of QL to manual

QL=(omega0*groupdelay)/2. This should be added to the S-parameter portion of the reference manual.

Documentation

TLINE grounded coplanar waveguide losses are not always included.

See Documentation

EMPOWER

EMPOWER memory usage was higher than expected in lossy case.

Uses 2-3 times expected memory

EMPOWER

Emport properties box said Length instead of Height

EMPOWER properties box, comment at bottom specifies "width and/or length", width and height are given

Equations

Using the FREQ variable without a linear simulation crashed

If the FREQ variable is used without a linear simulation, a GPF resulted.

Equations

Various Post-Processing Equations gave zero results.

The following operation doesn't work:
=.DB[S21]@1400-.DB[S21]@1600

Equations

GETVALUE first frequency point was sometimes missed


Error Messages

Automatically show errors/warnings flag is fixed

 

Error Messages

Interdigital Cap: Misleading error when substrate definition is iIncomplete

User is getting error when he tries to use MIDCAP model: Invalid use of operator (*) at (Unknown part/Line). Error was being caused by a missing parameter in substrate definition. Error is misleading. Version 7 didn't return any errors.

Export

DXF layer names cannot contain spaces.

The extra space in the layer name (e.g: TOP METAL) causes error messages in some CAD packages used for manufacturing.

FILTER

The Save Dialog box doesn't work as expected

FILTER is now integrated, no longer applies.

FILTER

Some hotkeys were duplicated

FILTER is now integrated, no longer applies.  Bandstop and Shunt C Coupled (Allpole BandPass) both use S as the hotkey.

FILTER

Show error when parts are negative

There should be some sort of indicator (an ERROR?) when negative values show up in a filter. Now, parts show purple.

Graphs

Smith Chart can crash if zoomed in to ridiculous range

 

Graphs

3D Graph can crash if no data defined.

 

Graphs

Graphing vertical axis log scale should be disabled.

Advanced Properties/Y axis/Log scale is disabled.

Graphs

Restore Default Graph Settings on Load does not work

This option was ignored.

Graphs

Graphs need better zooming

Now, toolbar, keyboard, and mouse wheel are supported.

Graphs

Add File/Export for Data Tables

Automatic export of text file from tabular output.

HARBEC

DC analysis gives zero results in some cases

When tuning, DC would sometimes give zero answers.

HARBEC

HB with many tones may take too long to initialize spectrum calculation

HB analysis, if there are very large number of tones (more 6) and large orders of harmonics of each tone.

HARBEC

Changing frequency to an undefined variable crashes the software

Change schematic frequency from 1000 to fo, without defining fo, crashes software.

HARBEC

Nonlinear Multitone sources DC use more nodes than necessary

If a circuit uses a n-tone source with DC<>0, then it is translated to n Spice SIN sources with the same DC value each, as result the DC value becames equal to n*DC.

HARBEC

Want to control simulation temperature & view noise in HARBEC

Would like to see the effect on noise and gain as temperature is varied.

HARBEC

In CURTICE3 model, specifying CRF but not RC gives inconsistent results

Specifying an extra output capacitance but not resistance gives different results in Harbec vs. Linearized simulation.

HARBEC

Nonlinear FET models STATZ_N noise parameters are not specified correctly

Instead, the model is interpreting FNC as flicker coefficient, typically a very small number like 12E-10. In other words, the model has put the wrong label on the variable it is asking the user for, causing the user to enter a number in the millions when in fact it should be getting a number in the picos or nanos.

HARBEC

Long Filenames with spaces fail in Spice link

For example "C:\Zipped Files\x.lib" fails.

Import

Importing version 4/5/6 CKT file with multiple substrates fails

 

LAYOUT

Feature Request: Add Step and Repeat to Layout

 

LAYOUT

Feature: Ability to Output GDSII Files

Support GDSII as layout output. This format is very popular for high-frequency work (on ceramic substrates) and for IC/semiconductor design.

Linear Simulation

W1=W2 in microstrip step, model creates null data

If W1=W2 in a step, the model should "disappear". Instead, the data goes invalid.

Linear Simulation

SBN model does not include reference plane shift

Stripline Bend Accuracy is now improved.

M/FILTER

Zero slide factor fails

A slide factor of zero in edge-coupled microstrip causes problems.

M/FILTER

M/FILTER: Electrical Variables sometimes displayed Physical Values

The Utilities|View Electrical Variables will often display the odd mode impedance where the coupling coefficient should be displayed. That is, K1=18.1850 is displayed instead of K1=0.00047.

M/FILTER

Write CKT File and escape causes loop

Now integrated into GENESYS, not an issue.

M/FILTER

M/Filter crashes when defaults are "bad"

Fixed various out-of-range problems.

Miscellaneous

First frequency problem when FREQ is used

When FREQ is called the first frequency is 0 Hz even if the real sweep starts at 100 MHz. Dividing by FREQ then causes an overflow and other problems.

Miscellaneous

Toolbars need to stay in docked position

Toolbars need to stay in docked position (stay where user put them).

Miscellaneous

Dialog boxes need HELP button

Dlg boxes need HELP button, not just F1 key for help.

Miscellaneous

Double-clicking in explorer to open file shows 8.3 abbreviated name

Double-clicking a WSP file in explorer to run GENESYS and load the file will show the filename and pathname with a Tilde.

Miscellaneous

Add option to dump table data to a file automatically.

Add a line to the table properties dialog to specify a filename where the data is automatically output in text format.

Miscellaneous

Variable Viewer cuts off variables with long names

Put a long name, "abcdefghijlkmnopqrs = 3.34134134" in the equations. Add a variable viewer output. The column won't be wide enough to see the result.

Miscellaneous

GENESYS changes file date on closure even if no changes

If you open a wsp file and make no changes, then just close it, the file date gets updated on the close.

Models

MIDCAP model needs to be improved

Interdigital Capacitor

Models

Stripline SLIO model does not work in LAYOUT

Offset Stripline: Variables for this model are (W) width, (A) offset from substrate center and (L) length. The problem is that Layout takes the (A) number and interprets it as Length.

Models

AIRIND AIRIND1 model unit of measurements are always mm.

Inductor model AIRIND1 (under lumped menu) appears to allow the user to switch in what units its variables are given. However, the model appears to continue assuming that the input numbers are in mm no matter what unit choice the user gives.

Models

Negation Block symbol should be improved

Negation symbol is not the right size. We should have some sort of port direction on it. It is very easy to accidentally reverse the negation block.

Models

MINV and MSUS don't work in LAYOUT.

Layout uses the wrong parameter for line length for inverted/suspended substrate lines.

Models

SPIND model too small in LAYOUT.

Spiral Inductor.

Models

Zero values cause models to give math errors

Zero values cause some models to blow up due to zeros in denominator.

Optimization

Want to be able to disable sets of optimization targets.

Can now right-click on opt/yield target in tree and deactivate.

SCHEMAX

Part Dialog is not remembering "show text" checkbox for text objects

Double clicking the text in Schemax will enable all text lines even if they have been previously hidden.

SCHEMAX

Make schematic curve elements look like curve

Make the curve elements in schemax look like a curve, it now looks like a straight segment

SCHEMAX

SBCP model is inconsistent

Stripline Broadside Coupled Lines.

SCHEMAX

Want an easy way to make schematics fit on the printed page

Making a schematic fit on the printed page is cumbersome: you have to guess the right size for the parts. Would like an automatic "fit to sheet" operator. (Added Fit to Page and Center to Schematic Menu.)

Statistics

Monte carlo setup variables Up/Down% are reversed.

 

Statistics

Yield optimizer reverts to old values after completion.

 

Synthesis

Allow easy reset of synthesis to factory defaults.

Added option on Create synthesis

Synthesis

FORMAT ERROR on entering numbers into Synthesis modules

Open MATCH and create a simple MATCH circuit. Change the port impedances away from 50 Ohms by opening the box and hitting the delete key to delete the "50". On deleting the last character, an error message box comes up - annoying.

Tuning

The errors/warning window terminates tuning

If you tune a parameter to a yellow condition, it terminates the tune because the error/warnings window grabs the focus.  Added local error messages/orange parts to prevent this.

*
*
 
*
*
*
*
*
*
*
 
*
*
*

.

Click Here for RSS Feeds Subscribe now for instant product, support, and application news!